Damped Oscillatory Wave Simulator
MODEL SWCS-932/S4
Conforming to ANSI/IEEE C37.90/1989




GENERAL


The Model: SWCS-932/S4 is intended to test damped oscillatory waves for surge immunity in a system including a static relay conforming to ANSI/IEEE C37.90.1.1989.




FEATURES

  • This unit is designed to apply damped oscillatory wave voltage to a commercial power supply so that the surge immunity can be easily evaluated.
  • Unlike the usual gap discharge type, a semi-conductor switch is employed to enhance the reliability.
  • As the generator circuit is floated, it is not necessary to float this unit even if a test is conducted in the transverse mode (interphase injection).
  • Up to 4kV of output voltage can be obtained, allowing flexible operation.
  • An output voltage limiting circuit is incorporated. As the output voltage power supply of this unit is not stabilized, the high voltage power output may fluctuate. In case the high voltage power supply output exceeds 4.5KV, this unit will automatically stop.


SPECIFICATIONS

Item Specifications
Surge output waveform Damped oscillatory wave
Frequency oscillation frequency 1MHz~ 1.5MHz (fixed within the range)
Repetition rate 50 or 60 Hz (synchronized to the driving power supply)
Output voltage range 1KV ~ 4KV (continuously variable)
Difference between output voltage and meter reading at SURGE OUT is ±10%.
Surge polarity Positive only
Rise time Rise time to the first peak voltage <=100ns
Envelop decaying to 50% of the crest value of the first peak In not less than 6 µs from the start of the wave (open circuit output at the surge out terminal)
Output impedance 150 ohm (150 ohm +20%, -0%)
Test duration 1 ~ 10S (Setting between 1 second and 10 minutes is available according to timer setting.)
Coupling capacitor 0.1µF
Power supply capacity of EUT AC240V Single phase or 3-phase 20A
DC120V 20A
Power supply Operating power supply voltage can be selected from among 100V, 110V, 120V, 200V, 220V and 240V according to a request.
Power consumption 25W or less
Operating temperature 15 ~ 35°C
Operating humidity 25 ~ 75%
Weight Approx. 12kgs (Except accessories)
Dimensions (W)430 x (H)200 x (D)400 mm (Except projection)



STANDARD ACCESSORIES

  • Line input cable
  • Short bar
  • Connector BNC-PR (for check terminal)
  • Lead wire for transverse (with plug)
  • Accessory bag
  • Instruction manual