GENERAL


The INS-AX2 series simulators are the advanced version of the conventional manually operated INS-4020/4040 simulators, maintaining the identical interference signal characteristics while offering a new level of ease of use.



FEATURES


  1. An innovative,motor driven coaxial switch mechanism eliminates the need to manually plug and unplug coaxial connectors, allowing a preset test sequence to be carried out seamlessly including pulse width and coupling mode changes, automatic voltage ramp and others.
  2. As well as manual control, the simulator can be remote-controlled through a fiber optic computer interface. A Windows control software package is supplied as an included accessory.
  3. Floating output
  4. 8 pulse widths installed: 10ns, 50ns, 100ns, 200ns, 400ns, 500ns, 800ns and 1000ns
  5. Internal switchable terminators
  6. Easily changeable and safety-interlocked outlet panel (EUT interface)
  7. 3 channels EUT fail input


SPECIFICATIONS


Item Model
INS-AX2-220/250 INS-AX2-420/450
Pulse output voltage 0.01 ~ 2.00kV±10% at 0.01kV step 0.01 ~ 4.00kV±10% at 0.01kV step
±0.04kV allowance for <0.1kV setting
When the output is terminated by the internal resistors.
Output polarity Positive or negative
Pulse Pulse width 50, 100, 200, 400, 500, 800, 1000ns ±10%, 10ns±3ns
Rise time <1ns
Output impedance 50 ohm system (53.5 ohm)
Pulse repetition mode Variable 10ms ~ 999ms±10% 16ms ~ 999ms±10%
Phase Injection phase angle 0 to 360 degrees±10 degrees
EUT power supply:>AC90V, 50/60Hz±10%
1 shot Single pulse generation, each time the 1 SHOT button is pressed.
Synchronized output with phase angle setting in PHASE mode
Power capacity of EUT INS-AX2-220:
Single phase AC240V/DC65V 20A
INS-AX2-250:
3-phase (4-wire) AC500V/DC250V 50A

50/60Hz±10%
NS-AX2-420:
Single phase C240V/DC65V 20A
INS-AX2-450:
3-phase (4-wire) AC500V/DC250V 50A

50/60Hz±10%
Power supply AC 100V~240V±10%, 50/60Hz±10%
Power consumption 110VA
Operating temperature and humidity range 15 ~ 35°C, 25 ~ 75% (No dewing shall occur.)
Dimensions W 430 x H 350 x D 470mm, projection excluded
Weight INS-AX2-220: Approx. 30Kg
INS-AX2-250: Approx. 38Kg
INS-AX2-420: Approx. 30Kg
INS-AX2-450: Approx. 38Kg
Mercury relay unit Model: 04-00014A Model: 04-00015A



TRIANGULAR PULSE ADDITION (Factory Option)


Parameters Specifications
Output pulse waveform Triangular pulse
Pulse output voltage 2kV (220/250) and 4kV (420/450) max (when the output is terminated by the internal resistors)
Output polarity Positive or negative
Pulse Duration 1µs±30%
Rise time <40 ns
When the triangular pulse generator has been built-in, the original model numbers become INS-AX2-220T/420T/250T/450T with an affix of "T".


STANDARD ACCESSORIES


INS-AX2-220/420 INS-AX2-250/450
Outlet panel (Single phase terminal block type) Model:18-00067A AC240VDV65V20A max Outlet panel (3-phase terminal block type) Model:18-00068A AC500VDV250V50A max
Power cable
Remote control software (CD-ROM) Model: 14-00033A
Optical conversion adapter
Optical cable (5m)
D-sub conversion connector
Instruction manual (for the simulator and remote control software)

Notice: Either 18-00067A (For INS-AX2-220/INS-AX2-420) or 18-00068A (For INS-AX2-250/ INS-AX2-450) is mounted on the simulator at shipment.


SOFTWARE DISPLAY EXAMPLES

FRONT PANEL / REAR PANEL

OPTIONS



For further information, please contact us at sales@noiseken.com.
Designs and specifications are subject to change without notice.