Note:
In consequence of the release of the new Impulse Noise Simulator Model: INS-AX2 Series,
the production of the Model:INS-200AX/300AX/400AX have been discontinued.
(2004-7)

IMPULSE NOISE SIMULATOR
MODEL INS-200AX/300AX/400AX


OPTIONS


Model: INS-300AX(IJ-02)



GENERAL


Used in combination with IJ-02 (filter superimposing unit), the INS-AX Series (control pulse generating unit) can accomplish high voltage pulse noise test. As in the case of any INS device, injection of the high voltage rectangular pulse (generated when the inductive load is released) with fast rise time to the power line of the equipment under test is possible.



FEATURES


  1. Simplified operation by the automated simulator. No necessity for troublesome work such as pulse width change, etc.
  2. User-friendly interactive interface using 7-inch display.
  3. Three modes --- manual mode, program mode and remote control mode are available.
  4. Functional programming and data loading / unloading using a memory card.
  5. External I/O provided for expanding the functions.


SPECIFICATIONS


Control pulse generating unit
Item Model
INS-200AX INS-300AX INS-400AX
Equipment control functions (1)Manual mode
(2)Program mode
(3)Remote control mode
Square wave output Pulse width Standard: 50ns, 100 ns, 800ns, 1µs *1)
Output voltage *2) 0 to 2000V 0 to 3000V 0 to 4000V
Polarity Positive/negative (Auto changing method)
Rise time Less than 1ns
Output impedance 50 ohm
Repetitive cycle Variable 20 to 100Hz 20 to 60Hz
One shot Injection to intended phase of power line by start switch
Line synchronization Synchronized to intended phase of 50Hz or 60Hz
External interface (Option) GP-IB, RS-232C
Remote control Control key, error operating key
External Event Input/Output Interruption :1, Parallel input output 8-bit
Power supply AC 100V/200V, 50/60Hz
Operating temperature range 0 to 40°C
Dimensions (W) 430 x (H) 200 x (D) 600 mm
Weight Approx. 30Kg

Filter Superimposing unit
Item Model
IJ-02 IJ-03
Power capacity of EUT AC 240V DC 65V
Single / 3-phase 30A *3)
AC 240V DC 65V
Singe / 3-phase 50A *3)
Phase change Automatic changing method
Common/normal mode change Automatic changing method
50 ohm terminal resistance Built-in
Operating temperature range 0 to 40°C
Dimensions (W) 430 X (H) 200 X (D) 600 mm
Weight Approx. 26Kg

*1) Pulse width (4 types) at intervals of 50ns from 50ns to 1µs are selectable.
*2) In case where 50 ohm terminal resistance is used.
*3) Solenoid switch provided

For further information, please contact us at sales@noiseken.com.