IMPULSE NOISE SIMULATOR
INS-4020/4040

For additional product information, please download the INS series brochure. INS-2005.PDF (1516KB)

Options
Injection unit


INS-4040


FEATURES


Impulse Noise Simulator INS-4020/4040 are more convenient and user-friendly than former models, thanks to the following features.

  • Push button setting for all parameters
  • Terminal block outlet panel
  • Sweep operation for output voltage, phase angle and repetition cycle
  • Up to 5 test settings stored in the momory
  • Floating output
  • Coupling mode selection by plugging the supplied coaxial connector to the selected port
  • Easily changeable mercury relay
  • Built-in 50 ohm terminator
  • Easily changeable outlet panels
  • CE marked


SPECIFICATIONS


Item Model
INS-4020 (2kV) INS-4040(4kV)
Output voltage 0.01 ~ 2.00KV ±10% with 50 ohm load, 10V step, Sweep mode available 0.01 ~ 4.00KV ±10% with 50 ohm load, 10V step, Sweep mode available
Polarity Positive or negative
Square wave Pulse width 50ns, 100 ns, 200ns, 250ns, 400ns, and any combination thereof, maximum width, 1µs or 10ns±3ns (the shortest connection)
Pulse rise time < 1ns
Output impedance 50 ohm system (53.5 ohm)
Pulse repetition mode Variable 10ms ~ 999ms±10%, 1ms step
Sweep operation available
16ms ~ 999ms±10%, 1ms step
Sweep operation available
Line phase 50 or 60Hz, Injection phase angle 0~359°, 1° step
Sweep operation available
External <EXT mode>
>10ms, Pulse width>1ms
TTL/Open collector negative logic
<EXT mode>
>16ms, Pulse width>1ms
TTL/Open collector negative logic

Also functions for timing reference signals input from an external injection unit
1 shot Single pulse injection to the angle which is specified by Line phase setting on the power line, or Single shot without injection power line.
Memory Up to 5 test settings
Power capacity of equipment under test AC 240V, DC60V, Single phase, DC60V 16A
Power supply AC100 ~ 240V 50/60H
Power consumption 140VA
Operating temperature and humidity 15~35°C / 25~75% (No dewing shall occur.)
Dimensions (W) 430 X (H) 249 X (D) 420 mm(Projections excluded)
Weight Approx. 19kgs

Included accessories
  • Coaxial cable Model: 02-00013A (8 pcs)
    • 30 cm length
  • SG short plug Model: 02-00106A (1pc)
  • Outlet panel Model: 18-00061B (1 pc)
    • Terminal block type
    • AC240V/16A DC60V/16A maximum
    • Leaves the factory with this panel attached to the main unit (INS-4020 or INS-4040)
  • AC cable (1pc)
    • AC100-115V 3-p, 2.4m
  • Instruction manual (English / 1 pc)



Option: Injection unit Model: IJ-4050                     Other options

The built-in injection circuitry has 16A rating for single-phase AC. For test exceeding this current limit or 3-phase application, IJ-4050 shall be used.

This optional unit can extend the EUT supply voltage and current ratings up to 3-phase AC 415V/50A. In conjunction with INS-4020/4040, this unit can operate in the EUT Line Synchronization mode.


SPECIFICATIONS


Item Model IJ-4050
Impulse input 8kV max when the INS-4020/4040 output is not terminated.
EUT power capacity 3-phase, 5-wire (L1, L2, L3, N, PE) AC415V, 50A
Coupling mode selection By short plug connection
Zero cross detection Detects L1-L2 voltage and outputs synchronization signal from the SYNC OUT connector
Dimensions and weight (W)430 x (H) 200 x (D) 535 mm (Projections excluded)
Approx. 25.0 kgs





For further information, please contact us at sales@noiseken.com.
Designs and specifications are subject to change without notice.