Insulation transformer unit TF-2302P |
|
|
|
|

Click here for enlargement |
- Maximum input voltage:
- Single phase 240VAC max (50/60Hz)
- Maximum Output current : 30A max.
- Dielectric strength:
- Primary to core: AC4kV (1 minute)
- Secondary to core: AC4kV (1 minute)
- Primary-secondary: AC4kV (1 minute)
- Insulation resistance
- 100M ohm or over at DC500V
- Weight :
Approx. 60.0 kgs
|
|
- Dimensions:
(W)350 x(H)475X(D)400mm (except eye bolt and handle)
- Included accessories
- AC single phase line input cable (3-core, 3m ) (1pc)
- PE cable (3m) (1pc)
- Instruction Manual (1pc)
|
 |
Insulation transformer unit TF-6503P |
|
|
- Maximum input voltage:
- Single or 3-phase 600VAC max (50/60Hz)
- Maximum Output current:
50A max.
- Dielectric strength:
- Primary to core: AC4kV (1 minute)
- Secondary to core: AC4kV (1 minute)
- Primary-secondary: AC4kV (1 minute)
- Insulation resistance
- 100M ohm or over at DC500V
- Weight :
Approx. 350 kgs
|

Click here for enlargement |
|
|
- Dimensions:
(W)500 x(H)640X(D)700mm (except eye bolt and handle)
- Included accessories
- AC 3-phase line input cable (4-core, 3m) connected to INPUT terminal of
this transformer (1pc)
- PE cable (3m) connected to the PE terminal of the transformer for earthing
connection (1pc)
- PE cable (3m) for connection of the simulator to the transformer (1pc)
.
- Instruction Manual (1pc)
|
 |
Memory Card 08-00003A
|
|
|
- A PCMCIA memory card, which is very common to notebook PCs, is adopted.
Test log and setting and screen hard copy files can be stored and
retrieved.
|
 |
Infra-red Remote Controller 08-00006B |
|

|
- A remote controller with the same function
as the control panel of the simulator can
be provided.
|
 |
Warning Lamp 11-00008A |
|
 |
|
 |
EUT interface 18-00048B |
|
Appearance of 18-00048B |
This unit provides a socket to put in a plug of the EUT when performing
an AC line test using the LSS-15AX. A
versatile socket is used so that the plug used in the various countries can be
put in.
- Maximum applying surge voltage: 15kV
- Socket rating (1)AC125V/15A (2)AC250V/16A
- Dimensions: (w)24 x(H)8x(D)36 cm
|
 |
Calibration cable set 05-00099A |
|
|
This product is the cable set for verifying output waveforms of the
LSS-AX series.
The following items are Included.
- Cable for voltage/length: Approx. 60cm (2 pcs)
- Cable for current/length: Approx. 120cm (1 pc)
- Dummy cap (3pcs)
- Instruction manual
For observing surge output waveforms of the LSS-15AX series, the following
instruments are necessary as well as this cable set.
- Oscilloscope: with differential calculation function (Ch1-Ch2)
- High voltage probe: 2 pieces. Withstanding voltage: More than 15kV.
- Current probe: using with current transformer. For observing surge
short-circuited current waveform
- Isolation transformer: for oscilloscope
- Earth cable: for connecting PE.
To avoid an inadvertent touch, covering tips of the HV probes with a protection cover is recommendable.
|