Lightning Surge Simulator
GENERAL Surges
represent transients that might be induced in cables by lightning. By their nature, fairly high energy charges may easily damage or upset
unprotected electronics circuits and components. Surges are not a new problem. Many companies have been testing their products at various stages of the
products life: design tests, qualification tests, production tests and
diagnostic tests. |
FEATURES |
Fully compliant with the requirements called for in the 2nd edition of IEC 61000-4-5 standard, the LSS-15AX series simulators provide
a testing facility for up to 15kV test voltage without sacrificing safety
and ease of use. The LSS-15AX simulators generate the two combination pulses
1.2/50 µs (8/20 µS) and 10/700 µS (5/320 µS).
|
FUNCTIONS |
|
Very intuitive settings can be done by the assistance of the well configured
user-interface consisting of a 5-inch LCD, ten-key, functions keys and
others. Coupling modes are graphically shown, allowing the operator to
select the desired mode and allows easy reference of settings when the
test is in progress. |
|
This button, easily accessible and placed
on the front panel, enables the operator
to stop the generation of the pulses anytime
he/she desires. In addition to the high voltage
power, the operator can turn off the EUT. |
|
A safely interlock is provided through the
special design high voltage connector. The
high voltage circuitry never be activated
when the connector is not correctly positioned
or not firmly locked. |
|
The value of the actual peak amplitude is
measured and shown for both voltage
and current. |
![]() |
|
|
The simulator automatically stops generating
the pulses if the peak current measured
exceeds
the threshold limit which can be freely
set
as the breakdown criteria. |
![]() |
SPECIFICATIONS |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DISPLAY EXAMPLES |
The following menus can be selected in the
menu display.
|
||
| MANUAL MODE TEST SETTING DISPLAY (1) When manual mode test is selected in the menu display, the corresponding test setting display will be shown. The output voltage, waveform and other test parameters can be set. Unnecessary items are indicated lightly and the simulator does not accept change in setting. |
![]() |
|
| MANUAL MODE TEST SETTING DISPLAY (2) Some items can be selected on pop up menus. The right example shows the choices on "Output To". |
![]() |
|
| AC/DC INJECTION SETTING DISPLAY Press the coupling mode key. Coupling mode selection screen will appear. The example shows the 3-phase AC CDN screen on which coupling and return lines can be set. On the telecom CDN setting screen the number of lines (2 or 4 lines), limit resistance (25 ohm or 40 ohm) and return line (1, 2, 3, 4 or PE) can be set. |
![]() |
|
TEST SET UP EXAMPLE Capacitive coupling on single-phase AC lines in Line-to-line & line-to-ground mode ![]() |
INCLUDED ACCESSORIES |