Top  >  Voltage Dip and Swell Simulator (VDS)  >  Voltage Dip and Swell Simulator VDS-1007/2007

Voltage Dip and Swell Simulator Model: VDS-1007/2007

 Product catalog

FEATURES

 

  • Enable to enrich EMC preliminary tests with the remote control as an AC stabilizing power source in the stand-alone

        VDS-1007 : 1kVA,    VDS-2007 : 2kVA

  • Enable IEC61000-4-11/13/14/28 precompliant tests  
  • Usable to be power source for IEC61000-3-2-2 precompliant measurement 
  • Enable to put out arbitrary waveforms and measure harmonics using the software (downloadable via our website) 

 

SPECIFICATIONS

< VDS-1007>

Items VDS-1007 specifications
Range 150V 300V 150V 300V
Output current capability AC 0 to 150V AC 0 to 300V DC 0 to 212V DC 0 to 424V
Load regulated output voltage variation 0.2%
Voltage set resolution 0.1V
Output current capability AC8Arms AC4Arms DC 4A DC 2A
Max. output current capability (Instant) 48Apeak 24Apeak 48Apeak 24Apeak
Frequency range DC 15 Hz to 1 kHz, 0.01Hz step, +/-0.15%
Rise time / Fall time (at interruption) 130 µsec (typ)
Voltage distortion 0.3% (50/60Hz)
Line / Load regulation 0.1 % (line)/ 0.2% (load)
Output impedance

Settable value: 0.0Ω+0.0mH to 1.0Ω+1.0mH 

0.01Ω step, 0.01mH step 

Phase angle setting 0 to 359.9° DEG, 0.1° DEG step
 Arbitrary waveform output, waveform library

50/60Hz up to 40th order

 External analog input up to 30 kinds.

Measurement function 11 kinds (Voltage, current, power, harmonics, power-factor, crest factor, apparent power, reactive power)
IEC Standards precompliant testing function AC source for IEC 61000-4-11, 4-13, 4-14, 4-28 and IEC 61000-3-2, 3-3
 Dip / Swell level

0%, 40%, 70%, 80% (0 to 32767%, 1% step (arbitrary))

within max. output voltage range

Repetition 1 to 65535 times, 1 step
Dip phase 0 to 359.9 deg, 0.1 deg step
Dip cycle 0 to 9999999 cycle, 0.1 cycle step
Interval cycle 0 to 9999999 sec., 0.0001 sec step
Voltage variation test
  • Fall set: 0 to 100000 cycle, 1 cycle step
  • Voltage hold set: 1 to 32767 cycle, 1 cycle step
  • Rise set: 0 to 32767 cycle, 1 cycle step
  • Repetition: 1 to 32767 times
Others
  • 3-phase output by 3 units parallel connection
  • Capacity increase by 2 units parallel connection.
  • Silence realizing design along load condition
  • Over voltage/over current/over power protection.
Power supply AC90 to 250V, 15A max., 47 to 63 Hz
Interface GPIB, RS232
Operating temperature  15°C to 35°C
Humidity range 25% to 75% (without dew)
Dimensions / Mass (W)438 x (H)134 x (D)610mm,  19.5kg
Included accessory
  • Captive cable 1 pc. 
  • Rear-foot
  • Instruction manual
  • Control software (downloadable via our website)

  <VDS-2007>

Items VDS-2007 specifications
Range 150V 300V 150V 300V
Output current capability AC 0 to 150V AC 0 to 300V DC 0 to 212V DC 0 to 424V
Load regulated output voltage variation 0.2%
Voltage set resolution 0.1V
Output current capability AC16Arms AC8Arms DC 8A DC 4A
Max. output current capability (Instant) 96Apeak 48Apeak 96Apeak 48Apeak
Frequency range DC 15 Hz to 1 kHz, 0.01Hz step, +/-0.15%
Rise time / Fall time (at interruption) 130 µsec (typ)
Voltage distortion 0.3% (50/60Hz)
Line / Load regulation 0.1 % (line)/ 0.2% (load)
Output impedance

Settable value: 0.0Ω+0.0mH to 1.0Ω+1.0mH 

0.01Ω step, 0.01mH step 

Phase angle setting 0 to 359.9° DEG, 0.1° DEG step
Arbitrary waveform output, waveform library

50/60Hz up to 40th order

 External analog input up to 30 kinds.

Measurement function 11 kinds (Voltage, current, power, harmonics, power-factor, crest factor, apparent power, reactive power)
IEC Standards precompliant testing function AC source for IEC 61000-4-11, 4-13, 4-14, 4-28 and IEC 61000-3-2, 3-3
 Dip / Swell level

0%, 40%, 70%, 80% (0 to 32767%, 1% step (arbitrary))

within max. output voltage range

Repetition 1 to 65535 times, 1 step
Dip phase 0 to 359.9 deg, 0.1 deg step
Dip cycle 0 to 9999999 cycle, 0.1 cycle step
Interval cycle 0 to 9999999 sec., 0.0001 sec step
Voltage variation test
  • Fall set: 0 to 100000 cycle, 1 cycle step
  • Voltage hold set: 1 to 32767 cycle, 1 cycle step
  • Rise set: 0 to 32767 cycle, 1 cycle step
  • Repetition: 1 to 32767 times
Others
  • 3-phase output by 3 units parallel connection
  • Capacity increase by 2 units parallel connection.
  • Silence realizing design along load condition
  • Over voltage/over current/over power protection.
Power supply AC90 to 250V, 28A max., 47 to 63 Hz
Interface GPIB, RS232
Operating temperature  15°C to 35°C
Humidity range 25% to 75% (without dew)
Dimensions / Mass (W)438 x (H)134 x (D)610mm,  20.5kg
Included accessory
  • Captive cable 1 pc. 
  • Rear-foot
  • Instruction manual
  • Control software (downloadable via our website)

  Designs and specifications are subject to change without notice.