Voltage Dip and Swell Simulator VDS-2002
Voltage Dip and Swell Simulator VDS-2002
Conforming to IEC 61000-4-11
- Voltage dip & swell simulator conforming to EN/IEC61000-4-11 Ed.3 (2020) Standard
- Multiple types AC plug receptacle on the front panel for easy connection of the EUT
- Easy setting for the test parameters on the front panel
- Realize flexible test conditions setting beyond the Standard with a PC remote control
- Enable to conduct the interruption test in DC (DC 125 V / 16 A max)
Specifications
Items | Specifications | |||
Number of lines | Single phase | |||
Test mode | Interruption AC/DC |
Local | Synchronous:Short circuit |
|
PC | Synchronous: Short circuit/ Open circuit Asynchronous: Short circuit/ Open circuit |
|||
Dip and swell | Local | Synchronous | ||
PC | Synchronous/ Asynchronous | |||
Variation | Local | Asynchronous (Only 2s-1s-2s standard defined test is available.) |
||
PC | Asynchronous | |||
Input voltage range | AC90~264V, 50/60Hz, DC0~125V | |||
Output voltage range | AC 0%~ 120% of input voltage, AC290V Max DC 0V-input voltage |
|||
Output VA | 4.224KVA (Continuous) | |||
Output current capability | AC |
100% of input voltage: 16A rms (Continuous) 80% of input voltage: 20A rms (<5S) |
||
DC | 16A (Continuous) | |||
Peak inrush current drive capability | AC 100~ 120V: >250A (at 100% output, <10mS) AC 220 ~240V: >500A (at 100% output, <10mS) |
|||
Load regulation |
100% of input voltage 0-16A rms: <5% 80% of input voltage 0-20A rms: <5% |
|||
Overshoot/ undershoot | <5% (100 ohm loaded) | |||
Rise time/ fall time | 1 ~ 5 µS (100ohm loaded) | |||
Normal voltage setting | Setting by percent | Local | 100% | |
PC | (4%) ~120% /10V minimum | |||
Setting by voltage | PC | 10V~290V/ 5V step | ||
Accuracy | ±5V (0V~16A output) | |||
Dip/swell level | Setting by percent | Local | Short circuit for 0% (Interruption), setting: 0/40/70/80/120% (5 steps) | |
PC | Short/Open selectable for 0% (interruption): 0~120% | |||
Setting by voltage | PC | Short/Open selectable for 0V (interruption): 0~290V(0~120%), 5V step | ||
Accuracy | ±5V | |||
Repetition of events (No. of events) | Local | 1,3, 5, 10, 30, 50,100, or continuous (8 steps) | ||
PC | 1~1,000 or continuous (1 event step) | |||
Interval cycle | Setting by cycle | Local | 1, 3, 5, 10, 30, 50, 100, 300, 500 cycles and 10s (10steps) | |
PC | 0.5 ~ 5,000.5 cycles (0.5 cycle step) | |||
Setting by time | Setting for short duration | PC | Synchronous: 1~100s (1s step) Asynchronous: 8.3ms~100s (0.1m step) |
|
Setting for long duration | PC | Asynchronous: 1s ~ 10h (1s step) | ||
Dip cycle | Setting by cycle | Local | 0.5, 1, 5, 10, 12, 25, 30, 50, 250, 300 cycles (10 steps) | |
PC | 0.01 ~ 5,000 cycles (0.01 cycle step) | |||
Setting by time | Setting for short duration | PC | Synchronous: 0.1ms~100s (0.1ms step) Asynchronous: 0.1ms~100s (0.1ms step) |
|
Setting for long duration | PC | Asynchronous: 1s ~ 10h (1s step) | ||
Dip phase (starting phase angle of events) |
Setting by phase angle | Local | Synchronous: 0,45,90,135,180,225,270,315 (8 steps, 45 degrees step) | |
PC | Synchronous: 0~359° (1° step) | |||
Setting by time | PC | Synchronous: 0~19.9 ms for 50 Hz (0.1ms step) 0~16.6 ms for 60 Hz (0.1ms step) |
||
Voltage variation test | Setting by time | PC | Ansynchronous: Changing time: 0.1s~10s (0.1s step) , At least 0.1s required for 10% change of input Changed time: 0~10s (0.1s step) Interval: 0~100s (0.1s step) Test level: 0~120% |
|
Memory | Local | 5 tests | ||
PC | 10 steps (Test sequence stored up to 10 steps when controlled by PC.) | |||
Equipment Input voltage | AC100~240V ±10%, 50/60Hz, 120VA | |||
External interface | Optical RS-232 | |||
Dimensions | 430(W) x 745(H) x 600 (D) mm (Projection excluded) | |||
Weight | Approx. 150 kG |
※The above specifications are based on the use of the optional Windows remote control software.
Accessorise
Items | Quantity | |||
Power Cable | 1 | |||
Operation Manual | 1 |