GENERAL

Surges represent transients that might be induced in cables by lightning. By their nature, fairly high energy charges may easily damage or upset unprotected electronics circuits and components. Surges are not a new problem. Many companies have been testing their products at various stages of the products life: design tests, qualification tests, production tests and diagnostic tests. 

The advance of surge suppression devices and technique does not lessen the importance of surge testing, but rather increases it, as the requirement to reduce power consumption and to increase the operational speed of semiconductors has become more demanding.  In addition, the issue of surge testing is attracting renewed interest since this form of immunity is now a must for almost all electronic products for access to the global market.

 

FEATURES

 

  • "Output voltage 15kV, current 7500A" which can conduct breakdown resistibility test
  • "50% reduction of the output interval" which can drastically reduce the test time
  • "Touch-panel" adopted for the easy test setting
  • "Multi-languages" for the easy operation processing available
  • "Indicator" which is linked with the test setting equipped
  • PC control available with the optional software
  • "Emergency stop" & "Interlock terminal" which secure the test operator equipped
  • "Output waveform monitor terminal" which can ease pre-checking of the waveforms prior to the actual test

  SPECIFICATIONS
  <Surge Generating Unit>

Parameter Specifications Remarks

1.2/50μs-8/20μs

Combination waveforms

Output voltage 0.5kV to 15kV ±10%

Front time 1.2μs ±30%

Duration 50μs ±20%

Output current 250A to 7500A ±10%

Font time 8μs ±20%

Duration  20μs ±20%

Common for the all models

Voltage step : 0.1kV step

The setting can be from 0kV

10/700μs-5/320μs

Combination waveforms

Output voltage  0.5kV to 15kV ±10%

Front time 10μs ±30%

Duration 700μs ±20%

Output current  12.5A to 375A ±10%

Front time 5μs ±20%

Duration  320μs ±20%

Models: C1/C3

Voltage step : 0.1kV step

The setting can be from 0kV

Output polarity  Positive / Negative  
Interval

10 sec. to 989 sec., depending on the set voltage 10 sec.  (<6kV)

 15 sec. and over in 10/700 μs waveform
Output impedance

1.2/50μs waveform : 2Ω ±10%

10/700μs waveform : 40Ω ±10%

 

 <AC/DC CDN> 

Parameter Specifications Remarks
Coupling surge waveform 1.2/50μs-8/20μs combination waveforms  
Max. coupling surge voltage / current Up to the values which can be set  

Coupling network

Correspondent to IEC61000-4-5

18μF: Between LINE - LINE (10Ω +9μF selectable)  
10Ω:  ±9μF Between LINE - PE (18μF selectable)  
Injection mode Between LINE - LINE, Between LINE - PE  
Power supply lines structure for EUT

Single phase AC: L/N/PE

DC : +/-/PE

Models : A1A / C1

3-phase AC : L1/L2/L3/N/PE (Common for single phase and 3-phase)

DC : +/-/PE

Models : A3A / C3
EUT power capacity AC240V/20A MAX.  50/60Hz,  DC125V/20A MAX Models : A1A / C1
AC500V/50A MAX.  50/60Hz.  DC125V/50A MAX Models : A3A / C3
Decoupling coil 1.5mH  
Phase angle control 0  to 360° ±10°  

  <CDN for Telecom lines >  (Only in models C1 and C3)

Parameter Specifications Remarks
Coupling surge waveform 1.2/50μs-8/20μs combination waveforms
10/700μs-5/320μs combination waveforms
 
Max. coupling surge voltage / current Up to the values which can be set  
Impedance matching resistors

40Ω

80Ω per 1 line at 2 lines

160Ω per 1 line at 4 lines

1.2/50 μs waveform

25Ω

0Ω per 1 line at 2 lines

100Ω per 1 line at 4 lines

10/700 μs waveform
Coupling mode Common mode / Normal mode  
Coupling network Gas arrestor : 90V  
Line for EUT  2 lines / 4 lines DC50V/100mA MAX Selectable
Decoupling coil 20mH  

 <Others>

Parameter Specifications Remarks
Voltage monitor      BNC output, 1/2000±10%        In open-circuit for SURGE OUT
Current monitor BNC output, 1mV/A±10%       In short-circuit for SURGE OUT
External communication   RS-232C optical communication  
Power supply   AC100V to AC240V ±10%, 50Hz / 60Hz  

Dimensions   
W555×H1450×D790 mm   (Models: A1A / A3A) Projection excluded
 W555×H1800×D790 mm   (Models: C1 / C3)  Projection excluded
Mass  Approx. 290 (Model:A1A),  Approx. 300kg (Model:A3A)  
 Approx. 3100kg (Model:C1),  Approx. 340kg (Model:C3)  

 

SELECTION GUIDE TABLE

 

 

Model

LSS-F02

Output waveform AC/DC Power Line CDN Telecom Line CDN

1.2/50 μs

(8/20 μs)

10/700 μs

(5/320 μs)

Single phase

AC240V/30A, DC60V/20A

Single and 3-phase

AC500V/50A, DC60V/20A

DC50 V 100mA
A1A Available   Available    
A3A Available     Available  
C1 Available Available Available   Available
C3 Available Available   Available Available

 STANDARD ACCESSRIES

 

     Items  Specifications/FUnctions  Quantity  Correspondent models
    Surge output cable HOT/COM  2 pcs. A1A/A3A/C1/C3
    Output cable to power supply lines For single phase : L / N / PE  3 pcs. A1A/C1
    For 3-phase : L1 / L2 / L3 / N / PE 5 pcs. A3A/C3
    Output cable to telecom lines For 1 to 4 lines and GND  5 pcs. C1/C3
    Arrestor unit For coupling : Equipped to main unit panel  4 pcs. C1/C3
    For input protection : Equipped to main unit panel 4 pcs.
    Cable for monitor BNC-BNC cable  1 pc. A1A/A3A/C1/C3
    External interlock connector 5P plug (Short between #1 - #3)  1 pc. A1A/A3A/C1/C3 
    Power supply cable For AC100V, 3P equipped with G connector cable  1 pc. A1A/A3A/C1/C3 
    High voltage connector cap Equipped to main unit panel  5 pcs. A1A/C1
    7 pcs. A3A/C3
    FG cable For grounding the body  1 pc A1A/A3A/C1/C3
    Instruction manual In Japanese/ English  1 each A1A/A3A/C1/C3

    Please download  LSS-F02 series brochure pdf  (1881Kbyte).

    LSS-F02 series brochre includes the information on the detailed futures, specifications, optional accessoreis, the summary of IEC 61000-4-5 ed.2.0 standatd, the test set up examples and others.

     

    Designs and specifications are subject to change without notice.