Top  >  Electrostatic Discharge Simulator (ESS series)  >  Discharge Gun GT-30R2KA/GT-30R3302KA

Discharge Gun GT-30R2KA/GT-30R3302KA

Discharge Gun GT-30R2KA / GT-30R3302KA

       Conforming to ISO10605

 

GT-30R2KA  Discharge Gun

Discharge gun stand (Model: PS-806) and Conversion Adaptor (Model:03-00074A) are optional accessories.  

 

FEATURES

     
  • Meets ISO10605 2nd edition>
  • 150pF-2K ohm capacitor/resistor unit and 330pF-2K ohm capacitor/resistor unit included (GT-30R2KA package).
  • All the 4 capacitor/resistor units included (GT-30R3302KA package).

 

SPECIFICATIONS

Items GT-30R3302KA GT-30R2KA
Output voltage

0.20~30.0kV ±5% (with ESS-S3011A/B3011A)

0.20~16.0kV ±5% (with ESS-L1611A)

Discharge mode Air discharge and contact discharge
Output polarity Positive / negative
Standard energy storage capacitor

150 PF±10% , 330 PF ±10%

Standard discharge resistor 330 ohm±10% & 2K ohm ±10% 2K ohm ±10%
Charging resistor Contained in the CR unit
Cable length 2 m
Charged voltage hold time 5 seconds or more
Dimensions

83.3(W) x 217.2(H) x 229.3 (D) mm

(Discharge tip excluded)

Weight Approx. 1300g  (cable and high voltage connector included)

 

STANDARD ACCESSORIES

 

GT-30R2KA (Set for 2K ohm Test under ISO 10605)
2Kohm testing discharge cup 03-00072A 

  

Discharge tip 12-00007A (Conical)

Discharge tip 12-00007A

For contact discharge test

Conforming to IEC 61000-4-2 and ISO 10605
 

 

 

 

CR unit 150pF-2k ohm 06-00074B 

CR Unit 06-00073A

Discharge tip 12-00008A (Round)

Discharge tip 12-00008A

For air discharge test

Conforming to IEC61000-4-2 and ISO 10605

CR unit 330pF-2K ohm 06-00076B

CR unit 06-00075A

Discharge tip 12-00009A  (SphericalΦ30mm)

Discharge tip 12-00009A  
 For high voltage (over 15kV) air discharge

 Conforming to ISO 10605 

  • Instruction manual  
  • GT-30R3302KA (Set for 330 ohm and 2K ohm Tests to ISO 10605)

    330 ohm testing discharge cup 03-00071A 


      

    Discharge tip 12-00007A (Conical)

    Discharge tip 12-00007A

    For contact discharge test

    Compliance Standards: 

    IEC 61000-4-2 Ed1.2 & Ed2.0

    ISO 10605 1st & 2nd Ed.
     

     

    CR unit 150pF-330 ohm 06-00073B 


    CR Unit 06-00073A

    Discharge tip 12-00008A (Round)

    Discharge tip 12-00008A

    For air discharge test

    Compliance Standards: 

    IEC 61000-4-2 Ed1.2 & Ed2.0

    ISO 10605 1st & 2nd Ed.

    CR unit 330pF-330 ohm 

    06-00075B

    CR unit 06-00075A

    Discharge tip 12-00009A (SphericalΦ30mm)


    Discharge tip 12-00009A  
     For high voltage (over 15kV) air discharge

    Compliance Standard: 

    ISO 10605 2nd Ed.

    2Kohm testing discharge cup 03-00072A 

      

    CR unit 150pF-2k ohm 06-00074B 

    CR Unit 06-00073A

    CR unit 330pF-2K ohm 06-00076A

    CR unit 06-00075A

     

    Instruction manual  

     

    COMBINATIONS OF DISCHARGE CUP AND CR UNIT

    By replacing the discharge cup and CR unit, this product allows the single discharge gun to output the output current waveforms that support two types of test standards (IEC 61000-4-2 and ISO 10605).  The combinations of the discharge cup and CR unit and their compliance test standards are as follows.

     

    Discharge Cup CR Unit Compliance Test Standard
    Discharge Cup for 330 ohm test

     

    150pF-330 ohm

    IEC 61000-4-2 Ed1.2
    IEC 61000-4-2 Ed2.0

    ISO 10605 2nd Ed (330 ohm test)

    330pF-330 ohm

    ISO 10605 2nd Ed (330 ohm test)
    Discharge cup for 2k ohm test  150pF-2k ohm ISO 10605 1st Ed (2k ohm test)
    ISO 10605 2nd Ed (2k ohm test)
    330pF-2k ohm ISO 10605 1st Ed (2k ohm test)
    ISO 10605 2nd Ed (2k ohm test)

    COMBINATIONS WITH ESD SIMULATORS

      This product is a discharge gun used to perform electrostatic tests.  Its available functions vary, depending on the simulator used in the combination with it.

       

      Simulator model Connectivity/Availability Functional restriction on this instrument
      ESS-S3011A Recommended combination No functional restrictions
      ESS-B3011A
      ESS-S3011  Recommended combination No functional restrictions
      ESS-B3011
      ESS-2000AX Can be connected and used but some functions are not available.

      The following functions are not available.
       

        

        Discharge detection
        Pre-check
        LED light illuminating EUT
        CR & cup combination recognition

      ESS-2002EX
      ESS-2000
      ESS-2002