Coupling Adapter CA-805B
CA-805B will be able to test the noise immunity by only coupling the cable of the electronic device by combining our tester. (Coupling ratio 1: 1)
- Noise can be injected without disconnecting signals, DC, AC, GND, etc.
- Noise immunity of electronic devices can be tested separately.
- Since noise can be injected directly into the signal line, etc. noise immunity can be effectively tested.
- Signal bundle wires with a maximum outer diameter of up to 26 mm can be coupled. Since noise can be coupled directly, noise immunity can be effectively tested.
Item | Specifications |
Input voltage | 4000V MAX |
Coupling type | Capacitive coupling |
Dimension/Weight |
(W)350 x (H)475 X (D)400mm / Approx.3kg |
Clamp's inner diameter | 26mm |
EMC-346
- 1EMS Probe Kit H2-B
- 2Outlet Box 18-00081A/82A/83A
- 3Warning Lamp 11-00008B
- 4Tri-Color Pilot Light 11-00015A
- 5Normal Mode Balun 15-00013A
- 6Coupling clamp 15-00012A
- 7Outlet box (terminal block type)
- 8SG terminal connection plate
- 9Noise application probe 01-00034A
- 10Radiation Probes 01-00006A/07A/08A/09A/10A/31A/50A
- 11
- 12Coupling Adapter CA-806(15-00007A)
- 13USB Optical Module 07-00022A
- 14Coupling unit (DC600V / 200A for high power capacity)
- 15Application fixture for high frequency surge-resistant test