Injection unit IJ-5100Z
Unit to enable the noise injection to power supply lines of EUT up to AC480V / 100A 3 pjase 5 lines (L1, L2, L3, N, PE) incombination with main units of INS series. In case of the combination with INS-4020 / 4040 / S220, test synchronized with EUT lines can be conducte.
Item | Specification |
Input impulse voltage | Max. 8kV without 50Ω termination Max. 4kV with 50Ω termination |
EUT Line | 3-phase 5 lines (L1, L2, L3, N, PE) AC415V 50A (Unavailable for DC) AC415V between L1-L2, L2-L3, L3-L1 AC240V between L1, L2, L3 – N |
Maxium voltage of EUT line | AC 480V |
Maxium current of EUT line | 100A |
Line synchronlzation output | 1/2 of EUT line input voltage |
Through characteristic | within -10db under 10kHz~1GHz |
CDN power supply | AC 100〜240V ±10%50/60Hz |
Dimension / Mass | (W)488×(H)520×(D)825mm (Projection excluded) / Approx 115kg |
EMC-374
- 1EMS Probe Kit H2-B
- 2Noise application probe 01-00034A
- 3Radiation Probes 01-00006A/07A/08A/09A/10A/30A/31A/50A
- 4Coupling Adapter CA-805B
- 5Coupling Adapter CA-806(15-00007A)
- 6Outlet Panel(for S220) 18-00059C/60B/84A
- 7Injection unit IJ-4050
- 8USB Optical Module 07-00022A
- 9Coupling Clamp 15-00014A
- 10Pulse Application Cable
- 11Injection Proble for High Frequency Surge Resistance Test (0.01μF, 470 pF)
- 12INS Direct Injection Condenser 01-00047A
- 13Automatic CDN for impulse noise tester IJ-AT450
- 14