Multi Noise Simulator (MNS) Multi Noise Simulator MNS-C41
EMC Compliance Testing, With NoiseKen Quality
MNS-C41 combines the key EMC immunity tests, such as Electrical Fast Transient/Burst (IEC 61000-4-4), Lightning Surge (IEC 61000-4-5), and Voltage Short Interruptions (IEC 61000-4-11), into a single platform. Purpose-built for EMC compliance testing, it streamlines the test process, enhances reliability, and provides a dependable testing environment that enables operators to work with confidence.

Specifications
- Supports EFT/Burst, Lightning Surge, and Voltage short Interruptions Testing
- Compliant with IEC 61000-4-4, IEC 61000-4-5, and IEC 61000-4-11
* Voltage Dip Testing (16A) also available optionally. Voltage Variation Testing is not supported. - Dedicated PC Control Software with Malfunction Judgement and Automated Report Generation functions.
- Dedicated Pre-Check Software for Efficient Daily Inspection
- Durable, Maintenance-Friendly Design for Long-Term Reliability
- Color Touch Panel with Excellent Visibility and Operability
- English and Japanese User Interface
Specification
● Electrical Fast Transient / Burst Test
■Generator Specifications
| Parameter | Specification | |
|---|---|---|
| Applicable Standard | IEC 61000-4-4 Ed.3:2012 Compliant | |
| Output Voltage | 200 V to 4500 V, 10 V Step | |
| Polarity | Positive / Negative | |
| Pulse Repetition Frequency | 0.1 kHz to 1000 kHz | |
| 0.1 kHz to 1 kHz /0.01 kHz Step 1.0 kHz to 10 kHz / 0.1 kHz Step | ||
| 10 kHz to100 kHz /1 kHz Step 100 kHz to 1000 kHz/10 kHz Step | ||
| Number of pulses | 1 to 1000, 1 Pulse Step | |
| Burst Duration | Calculated as:(Number of Pulses) / (Pulse Repetition Frequency) | |
| Directly Adjustable Range:0.01ms to 999 ms | ||
| Burst Period | 10 ms to 1000 ms ±10%, 10 ms Step | |
| Polarity Alternation Function | Not Available | |
| Continuous Pulse Output | Not Available | |
| Waveform Specification (50 Ω Load) Pulse Output | Pulse Peak Voltage:(Output Voltage / 2) ±10% Rise Time : 5 ns ±30% Pulse Width : 50 ns ±30% | Applicable Range Output Voltage: ±250 V to 4000 V Pulse Repetition Frequency: 5 kHz to 100 kHz |
| Waveform Specification (1 kΩ Load) Pulse Output | Pulse Peak Voltage:(Output Voltage x 0.95) ±20% Rise Time : 5 ns ±30% Pulse Width : 35 ns - 150 ns ±30% | |
■CDN Specifications
| Parameter | Specification |
|---|---|
| EUT Power capacity | Single-Phase AC 85 V - 240 V, 50/60 Hz, DC 125 V, 16 A |
| Application Phase | L / N / PE |
| Single Line, All Lines, or Individual Lines Selection | |
| Coupling Mode | Common Mode |
| Output Type | Terminal Block |
| Coupling Capacitor | 33 nF |
| Waveform Specification (50 Ω Load) | Pulse Peak Voltage:(Voltage Setting / 2) ±10% Rise Time: 5.5 ns(-1.5/+1.5) ns Pulse Width: 45 ns(-15/+15) ns Specified at: Voltage Setting: ±4000 V Pulse Repetition Frequency: 5 kHz to 100 kHz |
| Input residual voltage | 10% or less of the set pulse voltage Specified with EUT line inputs and outputs open-circuited |
| AC Line Synchronization | Mode: Synchronous / Asynchronous Phase Angle: 0° - 360° ±10°, 1° Step Min. Sync Voltage: AC 90 V or Higher Frequency: 50 Hz / 60 Hz ±10% |
● Lightning Surge Test
■Generator Specifications
| Parameter | Specification | ||
|---|---|---|---|
| Applicable Standard | IEC 61000-4-5 Ed.3:2014 Compliant | ||
| Output Voltage | 250 V ~ 4500 V 10 V step | ||
| Polarity | Positive / Negative | ||
| 1.2/50 μs - 8/20 μs Combination Wave | Voltage | Open-Circuit Voltage:250 V - 4500 V ±10% Front Time:1.2 μs ±30% Duration:50 μs ±20% Undershoot:≤ 30% of Peak Voltage | |
| Current | Short-Circuit Current : 125 A to 2250 A ±10% Front Time : 8 μs ±20% Duration : 20 μs ±20% Undershoot : ≤ 30% of Peak Current | ||
| Suge Generation Circuit Type | Floating | ||
| Repetition Period | 10 s to 999 s | ||
| Output Type | 4 mm Safety Plug | ||
| Pulse Voltage Monitor | BNC Output, 2000 V/V (±10%) Output accuracy: ±10% of actual output. | Open-Circuit Output (No Waveform Guarantee) | |
| Pulse Current Monitor | BNC Output, 1000 A/V (±10%) Output accuracy: ±10% of actual output. | Short-Circuit Output (No Waveform Guarantee) | |
■CDN Specifications
| Parameter | Specification | ||
|---|---|---|---|
| EUT Power capacity | Single-Phase AC 85 V - 240 V, 50/60 Hz DC 125 V, 16 A | ||
| Application Phase | L/N | ||
| Coupling Mode | Common Mode, Normal Mode | ||
| Output Type | Terminal Block | ||
| Coupling network | Common Mode: 10 Ω + 9 μF Normal Mode: 18 μF | ||
| Waveform Specification | Common Mode | Voltage | Open-Circuit Voltage: 250 V - 4500 V ±10% Front Time: 1.2 μs ±30% Duration: 50 μs (+10 μs / -25 μs) |
| Current | Short-Circuit Current: 20.8 A - 375 A ±10% Front Time: 2.5 μs ±30% Duration: 25 μs ±30% | ||
| Normal Mode | Voltage | Open-Circuit Voltage: 250 V - 4500 V ±10% Front Time: 1.2 μs ±30% Duration: 50 μs (+10 μs / -25 μs) | |
| Current | Short-Circuit Current: 125 A - 2250 A ±10% Front Time: 8 μs ±20% Duration: 20μs ±20% | ||
| AC Line Synchronization | Mode: Synchronous / Asynchronous Phase Angle: 0° - 360° ±10°, 1° Step Min. Sync Voltage: AC 90 V or Higher Frequency: 50 Hz / 60 Hz ±10% | ||
● Voltage Short Interruptions Test
| Parameter | Specification |
|---|---|
| Applicable Standard | IEC 61000-4-11 Ed.3:2020 Compliant (parameters listed below only) |
| Test Range | 0 V - 240 V |
| Frequency | DC, 50/60 Hz |
| Output Current | 16A |
| Inrush Current | 500 A Peak |
| Interruption Duration | 100 μs - 30 s |
| Fall Time / Rise Time | 1μs - 5 μs |
| AC Line Sync Output | 0° - 360°, 1° Step |
| Repetition Period | 10 ms - 999 s |
■ General Specifications
| Parameter | Specification |
|---|---|
| Power Requirements | AC 100 V - 240 V ±10%, 50/60 Hz |
| Power Consumption | 130 VA |
| Operating Environment | Temperature: 15°C - 35°C Relative Humidity: 25% - 75% |
| Dimensions | W 430 × H 349 × D 540 mm(Excluding Protrusions) |
| Weight | Approx. 50 kg |
■ Other Specifications
| Parameter | Specification |
|---|---|
| Emergency Stop Button | Push-Lock Pushbutton Switch |
| Interlock Terminal | Testing Stops When Open-Circuited |
| Pre-Check Function | PC Software-Based(Basic Waveform Verification) |
| EUT Line Input/Output Terminal | Terminal Block |
| LCD | Color Touchscreen |
| Language | Selectable: English / Japanese |
Optional AccessoriesProduct Name Model No. Description CDN Waveform Verification Connector 02-00169A Dedicated connector for verifying CDN output waveform. SG Terminal Connection Plate for MNS-C41 03-00145A Metal plate for connecting the SG terminal of the tester to the ground plane. Single-Phase Tap Transformer 17-00008A Transformer for voltage dips and short interruptions testing in accordance with IEC 61000-4-11.
*not an Isolation Transformer!Outlet Box for MNS(125 V, 15 A, 2P+PE) 18-00089A Outlet box for connecting EUTs, rated for 125 V, 15 A. JP/USA (Type A) Outlet Box for MNS(Multi-Type) 18-00090A Outlet box for EUT connection compatible with multiple outlet standards. Coupling Clamp 15-00018A Coupling clamp for communication line testing in accordance with IEC 61000-4-4. Clamp Calibration Fixture 15-00010A Fixture for verifying and calibrating the coupling characteristics of the coupling clamp. OPTICAL INTERFACE BOX 07-00022A Interface unit for optically isolated connection between the tester and a PC. MNS-C41 Pre-Check Kit 14-00078A Pre-check software for verification of MNS-C41 output waveform.
* Oscilloscope required separately.MNS-C41 RemoteW 14-00079A Dedicated software for remote control of the MNS-C41 from a PC.
Contact
Repair, Inspection and Calibration
Customer Service CenterNew Purchase Consultation, Materials Request
Product Inquiry Form