Damped Oscillatory Wave Simulator (SWCS) Damped-Oscillatory Wave Simulator SWCS-900 series
Damped-Oscillatory Wave Simulator simulates and generates the fast, repetitive high-frequency noise generated when switches and other switching devices turn ON/OFF, evaluating the immunity of electronic and electrical equipment. The SWCS-900-1M can perform tests compliant with the Japanese power standard B-402 (2007) and the IEC 61000-4-18 (Ed. 1.0) standard.

Features
- Tests compliant with IEC 61000-4-18 (2006) are possible.
- Outputs voltages up to 3kV, enabling ample testing.
- The touch panel provides a highly visible settings screen. *Languages supported include English
- Internal switching between common mode and normal mode, as well as phase switching, is possible.
- It incorporates a power line CDN (AC240V/DC125V 20A).
- Combination with high-capacity CDN is possible (optional)
■Output Waveform Image

■Software Operation Screen (Image)*
*Language is available in English
Specifications
■Specifications
Parameter SWCS-900-1M Specifications SWCS-900-100k Specifications Output Waveform Low-Frequency Damped Oscillatory Wave Floating Output Output voltage 250V to 3000V ±10% 1V steps short-circuit current 1.25A ~ 15A±20% Oscillation frequency 1MHz±10% 100kHz±10% Repetition frequency 400 / 480 Hz ±1%
400Hz = 8 times per cycle of 50Hz commercial frequency (asynchronous)
480Hz = 9.6 times per cycle of 50Hz commercial frequency (asynchronous)
400Hz = 6.7 times per cycle of 60Hz commercial frequency (asynchronous)
480Hz = 8 times per cycle of 60Hz commercial frequency (asynchronous)40 / 48 Hz ±1%
40Hz = 8 times per cycle of 50Hz commercial frequency (asynchronous)
48Hz = 9.6 times per cycle of 50Hz commercial frequency (asynchronous)
40Hz = 6.7 times per cycle of 60Hz commercial frequency (asynchronous)
48Hz = 8 times per cycle of 60Hz commercial frequency (asynchronous)Voltage Waveform Decay Rate The fifth peak exceeds 50% of the first peak, while the tenth peak is less than 50% of the first peak (reaching 50% of the peak value between the 3.5th and 5.5th cycles). Rise time 75 ns ±20% (between 10% and 90%) Output impedance 200Ω±20% Output Polarity Positive or Negative Imprint time 1s to 999s ±0.05s (1-second increments) and continuous Coupling capacitor 0.5µF±20% CDN Power Capacity Single-phase/Three-phase AC 240V 20A or DC 125V 20A Imprint Phase Normal Mode: L1 / L2 / L3 / N phase-to-phase
Common Mode: L1 / L2 / L3 / N phase-to-PE, L1, L2, L3 phase simultaneous application-to-PE, L1, L2, L3, N phase simultaneous application-to-PEDecoupling coil Below 1.5 mH Drive power supply AC 100V–240V ±10% 50/60Hz Power consumption Below 150VA Operating Temperature Range 15℃~35℃ Dimensions (W)430mm × (H)515mm × (D)500mm (excluding protrusions) Weight Approximately 53 kg ■Standard accessories
Name Q-ty AC cable 1 pc. Spare fuse for equipment power supply 2 pcs. Spare fuse for EUT line 4 pcs. Waveform Verification Jig (200Ω Termination Resistor + 40cm Braided Cable) 1 set User's Manual 1 copy Accessories bag 1 pc. Contact
Repair, Inspection and Calibration
Customer Service CenterNew Purchase Consultation, Materials Request
Product Inquiry Form
Options
Related Products
News
Contact
Repair, Inspection and Calibration
Customer Service CenterNew Purchase Consultation, Materials Request
Product Inquiry Form
-

ESD Simulator ESS-S3011A/GT-30RA
https://www.youtube.com/watch?v=kdKCHXaVhf8