Fast Transient Burst Simulator(FNS)   Attenuator for waveform check MODEL : 00-00017A
Attenuator for measuring high voltage pulse.

Specifications
Parameter | Specification |
---|---|
Attenuation rate | DC 〜 2 GHz:40 dB (100:1) |
Input pulse peak voltage | 4000 V MAX |
Tolerable continuous pulse examples | Repetition Frequency:≦ 5 kHz Burst duration:≦ 15ms Burst period:≧ 300ms, (Assuming IEC 61000-4-4 pulse waves) |
Input impedance | 50 Ω (50 Ω ± 1% at DC) |
Output impedance | 50 Ω (50Ω ± 1% at DC) |
Interface connectors | INPUT:HN (F) OUTPUT:N (F) |
Dimensions/ Weight | (W)154.5 mm x (D)105 mm x (H)37 mm approx. 1350 g |
Contact
Repair, Inspection and Calibration
Customer Service CenterNew Purchase Consultation, Materials Request
Product Inquiry Form
Fast Transient Burst Simulator(FNS) Options
-
Coupling unit (DC600V / 200A for high power capacity) -
Coupling Fixture for High Frequency Surge Test
-
Warning Lamp
MODEL : 11-00008B -
Optical USB module MODEL : 07-00022A -
High power Coupling Decoupling Network
-
Coupling Adaptor
MODEL:15-00007A (CA-806) -
Tri-color pilot light MODEL:11-00015A -
Coupling Adaptor
MODEL:CA-805B -
Coupling Clamp MODEL:15-00018A -
Coupling Clamp MODEL:15-00012A -
Radiation Probes MODELS:01-00006A/ 7A/8A/9A/10A/31A/50A -
Noise Injection Probe
MODEL: 01-00034A -
EMS Probes Kit
MODEL : H2-B -
SG terminal connection plate
-
Normal mode coupling balun
MODEL:15-00013A -
OUTLET BOX
(terminal block type) -
OUTLET BOX
MODEL:18-00081A/82A/83A