Lightning Surge Simulator (LSS)   CDN dedicated to DC power supply coupling for lightning surge tester (DC500V / 60A)
This tester by combining the lightning surge tester, it is possible to perform noise superim-position tests up to DC500V 60A.
In combination with the lightning surge tester body, you can perform tests by switching the applied phase and setting the applied phase sweep.
※When using this superimposition unit, it is necessary to modify the tester body. Please con-tact us for details.

Features
- By using the CHAdeMO connector for the EUT line INPUT / OUTPUT, you can easily perform the DC power supply superimposition test in combination with the light-ning surge tester.
- The tester can be controlled only by operating the surge tester.
※The CHAdeMO connector needs to be prepared by the customer.
※This product is a customized product. Please contact us for details.Specifications
Item Function / Performance s Remarks Coupled surge waveform 1.2/50μ s- 8/20μs combination waveform Maximum coupling surge voltage/current 4.5kV ※1 Coupling circuit 18μF ± 10% Line-to-line DC coupling output waveform Open circuit voltage: 0.5kV to 4.5kV ± 10%
Crest length: 1.2μs ± 30%
Wave tail length: 50μs + 10μs / -10μs
Short-circuit current: 250A to 2250A ± 10%
Crest length: 8μs ± 20%
Wave tail length: 20μs±20%Coupling circuit: 18 μF
Reduced coupling coil: 1.5mH
Cable length: 0.5m on one side
Line input side open
※ 2Discharge mode Line-to-line Coupling circuit: 18 μF Power line configuration for EUT DC:+/- ※3 Power line power capacity for EUT DC500V/60A Reduced coupling coil 1.5mH (standard)
1.3mH / 1.0mH / 0.8mH※4
※5※1: The surge input voltage / current can be up to the maximum value of the generator LSS-F03A3QN2283-02, but the applicable voltage / current at the output end of the CHAdeMO connector is not guaranteed because it depends on the specifications of the CHAdeMO connector.
At the time of shipment of this unit, 4.5kV is inspected as the maximum surge voltage at the “surge output section”.
※2: Specified by the output of the surge measurement terminal. There is no guaranteed waveform at the CHAdeMO connector output end.
※3: Surge is applied only to the DC power supply line. It cannot be applied to the signal line inside the CHAdeMO connector.
※4: The output waveform of the superimposed part is guaranteed only when 1.5mH is set. There is no guarantee of waveform when the value is lowered.
※5: Manual switching with a plug. When testing, set the same value for both lines.Contact
Repair, Inspection and Calibration
Customer Service CenterNew Purchase Consultation, Materials Request
Product Inquiry Form
Lightning Surge Simulator (LSS) Options
-
For Lightning Surge Simulator
CDN UNIT (AC600V / 300A) -
Telecom waveform check cable set
MODEL : 05-00150A -
Waveform Checking Cables Set
MODEL : 05-00099A -
Terminal Connection Board with Multi-Outlet(3P)
MODEL : 18-00048B -
Terminal Block for 3P
MODEL:18-00047A -
Terminal Block for 5P
MODEL:18-00044A -
DC line input cable
MODEL : 05-00136A -
AC line input cable
(3-phase) MODEL : 15-00135A -
AC Line Input Cable
(Single phase) MODEL : 05-00134A -
Arrester capacitor unit
MODEL : 08-00016A -
Arrester capacitor unit
MODEL : 08-00012A -
USB Optical Module Kit
MODEL : 07-00022A -
Warning Lamp
MODEL : 11-00008A -
Protective Safety Fence
MODEL : 11-00010A -
EUT Protective Safety Box
MODEL:11-00006A -
CDN for Interconnection Lines
MODEL : LSS-INJ6401SIG -
Isolation Transformer
MODEL : TF-6633P -
Isolation Transformer
MODEL : TF-6503P -
Isolation Transformer
MODEL : TF-2302P -
High-speed communication lines CDN
MODEL : F-130814-1004